ISO 172-1978 塑料酚-测模塑件游离氨的检验

作者:标准资料网 时间:2024-05-10 03:36:09   浏览:8092   来源:标准资料网
下载地址: 点击此处下载
【英文标准名称】:Plastics;Phenol-formaldehydemouldings;Detectionoffreeammonia
【原文标准名称】:塑料酚-测模塑件游离氨的检验
【标准号】:ISO172-1978
【标准状态】:现行
【国别】:国际
【发布日期】:1978-08
【实施或试行日期】:
【发布单位】:国际标准化组织(IX-ISO)
【起草单位】:ISO/TC61
【标准类型】:()
【标准水平】:()
【中文主题词】:氨;模制材料;塑料;铸件;酚醛树脂;检测;酚醛塑料
【英文主题词】:Ammonia;Analysis;Castings;Chemicalanalysisandtesting;Detection;Determinationofcontent;Mouldedparts;Mouldings(shapedsection);Phenolformaldehyde;Phenolicplastics;Phenolicresins;Phenoplastmouldedmaterial;Plastics;Verification
【摘要】:Specificationofaqualitativemethodofdetectingthepresenceoffreeammoniaorothervolatilebasesinphenol-formaldehydemouldingsbytheexposureofanindicatorpapertothevapourfromamoistenedpowderedsample.Itmaybeusedwhentheabsenceoffreeammoniaisarequirement.
【中国标准分类号】:G31
【国际标准分类号】:83_140_99
【页数】:1P.;A4
【正文语种】:英语


下载地址: 点击此处下载
基本信息
标准名称:石油化工企业生产装置电信设计规范
英文名称:Code for design of production plant telecommunications for petrochemical enterprises
中标分类: 电工 >> 电气照明 >> 电气照明综合
发布日期:1990-09-01
实施日期:1991-06-01
首发日期:
作废日期:
出版社:中国石化出版社
出版日期:
页数:13页
适用范围

没有内容

前言

没有内容

目录

没有内容

引用标准

没有内容

所属分类: 电工 电气照明 电气照明综合
【英文标准名称】:StandardTestMethodforMeasuringExtremeHeat-TransferRatesfromHigh-EnergyEnvironmentsUsingaTransient,Null-PointCalorimeter
【原文标准名称】:用瞬变零点量热器测量高能环境的超级传热速率的标准试验方法
【标准号】:ASTME598-2008
【标准状态】:现行
【国别】:美国
【发布日期】:2008
【实施或试行日期】:
【发布单位】:美国材料与试验协会(US-ASTM)
【起草单位】:E21.08
【标准类型】:(TestMethod)
【标准水平】:()
【中文主题词】:
【英文主题词】:calorimeter;convective;heatflux;heatfluxgage;null-point;radiative;transienttemperature;Calorimeter--aerospaceapplications;Convectiveenergy;Extremeheattransferrates;Heatflux;Heatingtests--aerospacematerials;Heattransfer;Trans
【摘要】:Thepurposeofthistestmethodistomeasureextremelyhighheat-transferratestoabodyimmersedineitherastaticenvironmentorinahighvelocityfluidstream.Thisisusuallyaccomplishedwhilepreservingthestructuralintegrityofthemeasurementdeviceformultipleexposuresduringthemeasurementperiod.Heat-transferratesrangingupto2.84x00D7;102MW/m2(2.5x00D7;104Btu/ft2-sec)(7)havebeenmeasuredusingnull-pointcalorimeters.Useofcoppernull-pointcalorimetersprovidesameasuringsystemwithgoodresponsetimeandmaximumruntimetosensorburnout(orablation).Null-pointcalorimetersarenormallymadewithsensorbodydiametersof2.36mm(0.093in.)press-fittedintothenoseofanaxisymmetricmodel.Sourcesoferrorinvolvingthenull-pointcalorimeterinhighheat-fluxmeasurementapplicationsareextensivelydiscussedinRefs(3-7).Inparticular,ithasbeenshownbothanalyticallyandexperimentallythatthethicknessofthecopperabovethenull-pointcavityiscritical.Ifthethicknessistoogreat,thetimeresponseoftheinstrumentwillnotbefastenoughtopickupimportantflowcharacteristics.Ontheotherhand,ifthethicknessistoosmall,thenull-pointcalorimeterwillindicatesignificantlylarger(andtimedependent)valuesthantheinputorincidentheatflux.Therefore,allnull-pointcalorimetersshouldbeexperimentallycheckedforpropertimeresponseandcalibrationbeforetheyareused.Althoughacalibrationapparatusisnotverydifficultorexpensivetofabricate,thereisonlyoneknownsystempresentlyinexistence(6and7).Thedesignofnull-pointcalorimeterscanbeaccomplishedfromthedatainthisdocumentation.However,fabricationofthesesensorsisadifficulttask.Sincethereisnotpresentlyasignificantmarketfornull-pointcalorimeters,commercialsourcesofthesesensorsarefew.Fabricationdetailsaregenerallyregardedasproprietaryinformation.Someusershavedevelopedmethodstofabricatetheirownsensors(7).Itisgenerallyrecommendedthatthecustomershouldrequestthesuppliertoprovidebothtransientexperimentaltimeresponseandcalibrationdatawitheachnull-pointcalorimeter.Otherwise,theendusercannotassumethesensorwillgiveaccurateresults.Interpretationofresultsfromnull-pointcalorimeterswill,ingeneral,bethesameasforotherheat-fluxsensorsoperatingonthesemi-infinitesolidprinciplesuchascoaxialsurfacethermocouplesandplatinumthin-filmgages.Thatis,theeffectsofsurfacechemicalreactions,gradientsinthelocalflowandenergyfields,thermalradiation,andmodelalignmentrelativetotheflowfieldvectorwillproducethesamequalitativeresultsaswouldbeexperiencedwithothertypesofheatfluxsensors.Inaddition,signalconditioninganddataprocessingcansignificantlyinfluencetheinterpretationofnull-pointcalorimeterdata.1.1Thistestmethodcoversthemeasurementoftheheat-transferrateortheheatfluxtothesurfaceofasolidbody(testsample)usingthemeasuredtransienttemperatureriseofathermocouplelocatedatthenullpointofacalorimeterthatisinstalledinthebodyandisconfiguredtosimulateasemi-infinitesolid.Bydefinitionthenullpointisauniquepositionontheaxialcenterlineofadisturbedbodywhichexperiencesthesametransienttemperaturehistoryasthatonthesurfaceofasolidbodyintheabsenceofthephysicaldisturbance(hole)forthesameheat-fluxinput.1.2Null-pointcalorimetershavebeenusedtomeasurehighconvectiveorradiantheat-transferratestobodiesimmersedinbothflowingandstaticenvironme......
【中国标准分类号】:A54
【国际标准分类号】:17_200_10
【页数】:10P.;A4
【正文语种】:英语